CONNEXIONS
- Benchmark UHF Radio Messaging System
- Transmit Data from Fire, Security and Nurse Call Systems
- Send Messages from PC
Flexibility
The key advantage of the Scope Connexions system is its flexibility.
Its modular high-performance interfaces enable robust connectivity to many different types of host device, including: internal telephone, PC network – Ethernet (optional), RS232, RS485, USB serial interfaces, and dry-contacts and voltage triggers.
There is also an internal protocol conversion option, which enables the translation of incoming RS232 data from host hardware into paging data, providing paging from various fire, intruder, nurse call, building management systems etc.
The basic unit comes with two RS232 ports and eight dry contact inputs, which enables the system to be hard wired to anything ranging from an alarm control panel to a doorbell.
We supply Connexions systems configured with default settings and which can support up to 4-digit pager numbers as standard (9999), enabling future expansion.
Working at UHF frequencies gives an extraordinarily high degree of reliability for transmissions in commercial environments, whilst using very small and unobtrusive antennas.
Key Features
- Standard model has two RS232 ports and 8 volt-free trigger inputs
- Optional telephone interface with voice prompts and programmable text messaging (programming pack required)
- Connex Page PC paging option which can access multiple Connexions transmitters over LAN or VPN
- Optional Internal Protocol Conversion module to enable data from third party panels to be paged. Most major fire panels, security panels and nurse-call systems are supported (phone for more details)
- High quality transmitter modules provide rock-solid RF performance. Standard (CX6) and high power (CX5) versions available
- Ranges of up to a mile are possible with the basic antenna supplied, external antennas and transponders can be added to improve coverage on difficult sites.
- UHF POCSAG signalling format ensures excellent propagation even in difficult environments
Mains Powered Version
DC Version
RF Output Power
Frequency Range
100-240V AC 0.5A 50/60Hz
12-14V dc, <50mA standby, 800mA transmit
1W max
446 to 469.700 MHz
Connexions 6
Mains Powered Version
DC Version
RF Output Power
Frequency Range
100-240V AC 0.8A 50/60Hz
12-14V dc, <50mA standby, upto 2.4A transmit
1W to 5W (2W ERP max for UK)
446 to 464.00 MHz
Connexions 5
Footprint
(excluding aerial)
330 (L) x 190 (W) x 70 (D) max
All Versions
See data sheet for full specification
Scope’s policy is one of continuous development and specifications are subject to change without prior notice